Stopping cleanly so the machine restarts trouble-free

A clean shutdown clears sludge from the machine and leaves the screen washed, preventing solids from drying inside the unit and causing a blinded screen or high starting torque at the next start.

Shutdown sequence

  1. 1
    Stop the sludge feed

    Stop the feed pump but keep the screw turning to clear sludge already inside.

  2. 2
    Stop polymer dosing

    Once no more sludge is arriving, stop the polymer to avoid waste.

  3. 3
    Run the machine empty

    Let the screw run until the remaining cake has discharged.

  4. 4
    Run a full wash cycle

    Wash the screen thoroughly to remove residual solids from the rings.

  5. 5
    Stop screw and wash-water

    Stop the screw, then the wash-water, and leave the unit ready for restart.

For extended shutdowns

  • Flush polymer lines with clean water to prevent gelling and blockage.
  • Consider protecting the machine against freezing where applicable.
  • Record run hours and note any observations for the next start.